LD-6600 Surface Imaging Logging System - Product
Place of Origin : Xian,China
Delivery Time : 30DAYS
Payment Terms : L/C
Product Description
The system is composed of four main parts, they are: a Control Rack, a Display and Operating Desk, a Power Supply Rack and a Truck Depth Panel SDDP-C. The Control Rack consists of a Perforating and Coring Panel (CSP), a Signal Switchover Cabinet (CIP), an Acquisition Interface Cabinet (GEP), an Electrode Array Logging Panel (DJXP), an Interface Cabinet of DITS (DEMP), an AC Power Cabinet of DITS (ELGAR), a USP and an AC Power Control Panel (ACCP); The Display and Operating Desk consist
Physical Specification
Other Specification : 1 Environmental Specifications
Operating Temperature 0℃ ~ +50℃
Deposit Temperature -20℃ ~ +75℃
Relative Humidity <95%
Vibration 3D, 3G, 10~60Hz (not Working)
Shock 3D, 10G, 10~60Hz, 11ms (not Working)
2 Main Power Supply 220VAC, 50Hz
3 Logging Main Computer
P4, 2.6G 80G/512M,
ReWritable CD-ROM
10/100M,
19”LCD.
4 Acquisition Interfaces
L Main Control Computer 300M,10/100M, -25℃ ~ 70℃
L Acquisition Channels:
Telemetry Channel 8Kb/s AMI Code, 100Kb/s BPSK Code, 5.192Kb/s M Code
Analogue Channel 23 Channels, Input: ±10V 12-bit A/D
Program-controlled Gains: ×1,×2,×4,×8,×16.
D/A Output 2 Channels, Output:: ±10V 12-bit
Pulse Count Channel 8 Channels, 16-bit Counter, Max. Frequency: 1MHz
Sonic H.S. Acqui-Channel Sampling Freq.: 0.5 MHz/1MHz, 12 Bit, A/D Conversion
5 Depth System
Max. Depth: 9999.99m, Max. L.S.: 10000m/h
5.7” EL Display
6 Power Supplies Of Down Tools
Main AC: 0 ~ 800VAC, 1A
Aux. AC: 0 ~ 800VAC, 1A
Relay Power:±150V, 1A
Adjustable AC: 0 ~ 250VAC, 0 ~ 500Hz, 1200W
Adjustable DC: Max. ±600VDC, 3.4A
7 Data Recording
It Provides LA716 And LIS Etc., Formats Of Data Records. Raw Data And Calculated Data Can Be Recorded Simultaneously.
8 Media Of Data Records
820DL/G Thermal Plotter, And DAT.