AC/DC Reactors - Product
Place of Origin : Shenzhen,China
Delivery Terms : Express
Delivery Time : 7 Days
Product Capacity : 10000pcs Per Month
Payment Terms : T/T Or Paypal
Product Description
AC reactor is used to prevent harmonics mainly generated by power source of inverter. It helps to ensure long time running of equipment by absorbing power disturbances which may otherwise damage motors and drives. Hence, the low voltage reactor is able to increase drive reliability of equipment.
Basic Information
Brand : Sikes
Material : Cooper Wire And Silicon Steel
Expiry/Validation Period : 6 Months
Physical Specification
Size or Volume : Customized
Weight : Customized
Other Specification : 1. AC Reactor Is Used To Prevent Harmonics Mainly Generated By Power Source Of Inverter. It Helps To Ensure Long Time Running Of Equipment By Absorbing Power Disturbances Which May Otherwise Damage Motors And Drives. Hence, The Low Voltage Reactor Is Able To Increase Drive Reliability Of Equipment.
2. It Is Devided Into Two Type:
The Pressure Drop Of The Benchmark Ud=2%, Used For No Feeder Unit Inverter;
The Pressure Drop Of The Benchmark Ud=4%, Used For Belt Feeder Unit Inverter.
3. Used To Limit The Current Impact Of Power Grid Voltage Fluctuation And Operating Over-voltage.
Smooth Powder Supply Voltage Contain Spikes, Or Smooth Commutation Bridge Rectifier Voltage Generated Defects.
4. It Not Only Prevents The Interference From The Powergrid But Also Reduce The Overall Flow Cell On The Grid Harmonic Current Generated By The Pollution.
5. Suitable For: System Has Several Inverters Joint In Parallel; Obviously Disturbing From Other Equipments Of The Power Circuit; Unbalance Voltage(exceed 1.8% Of The Nominal Voltage) Among Power Circuits; Inverters Is Powered By Low Resistance Cricuit; Equipment Contains One Power Factor Correction Equipment.
Technique Specification
1, Rated Input Voltage: 380V/660V/1140V
2, Reactive Strength: Core-Winding 3000VAC/50Hz/60S Free Of Arcing Breakage
3, Insulation Resistance: Core-Winding 500VDC,insulation Resistance ≥100MΩ
4, Reactor’s Noise Is Less Than 65dB(to Be Measured At The Point 1 Meter Away From The Reactor Horizontally)
5, Protection Class:IP00
6, Insulation Class: F/H
7, Standard: IEC289:1987 Reactor GB10229-88 Reactor(equivalent To IEC289:1987)
JB9644-1999 Reactor For Semi-Conductor Transmission
GB6450-86 Equal To National Standard IEC 726(1982) Dry Type Powder Transformers
8. Environment Exists Without Gas, Steam, Chemical Deposition, Dust Or Dirt That Will Affect Transformer’s Insulation Seriously.