Metal Sheathed 110 - 220KV XLPE Insulated Underground High Voltage Power Cables YJLW02 - Product
Place of Origin : Beijing,China
Delivery Time : Negotiable
Product Description
Metal Sheathed 110 - 220KV XLPE Insulated Underground High Voltage Power Cables YJLW02
High-voltage 110~220KV XLPE Cable
Brief introduction of the 110~220KV XLPE high-voltage cable products:
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable.
- - - -
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable for the places with a higher underground water lev
Physical Specification
Other Specification :
Metal Sheathed 110 - 220KV XLPE Insulated Underground High Voltage Power Cables YJLW02
High-voltage 110~220KV XLPE Cable
Brief Introduction Of The 110~220KV XLPE High-voltage Cable Products:
1. The Cross-linkage PE Insulated And Wrinkled Aluminum Wrapper Waterproof PVC Sheathed Power Cable.
- - - -
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable For The Places With A Higher Underground Water Level And To Be Used Underground, In The Tunnels Or Pipes. Such Cables Bear A Bigger Pulling Force And Pressure. |
- - - -
2.The Cross-linkage PE Insulated And Wrinkled Aluminum Wrapper Waterproof PE Sheathed Power Cable.
- - - -
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable For The Places With A Higher Underground Water Level And To Be Used Underground, In The Tunnels Or Pipes. Such Cables Bear A Bigger Pulling Force And Pressure. |
- - - -
Specific Property For Usage Of 110KV~220KV XLPE High-voltage Cable:
1. Cables Conductor Highest Working Temperature Is Allowed Up To 90, And Overload When Meet An Emergency Is 130 , When Short Circuit (in 5 Seconds) The Highest Temperature Is 250
2. When Installing Or Laying Cable, The Ambient Temperature Should Be Less Than -20, And Have To Give A Preheat To Cable.
3. The Minimum Bending Diameter:
- - - -
Cable Type Bending Diameter | Metal Sheathed |
After Laying | 30D0 |
During Laying | 40D0 |
- - - -
Note: In Form, D0 Is A Real Test Value To Cables Outer Diameter.
4. Allowed Biggest Axial Traction Force To Outer Diameter When Laying Cable (not Consider The Radial Lateral-pressure At Bent Set Ion) T=Kcore NO. Section (kg), In Formula, The Coefficient K Value Should Be: The Copper Core Get 7, The Aluminum Core Get 4.
5. Allowed Biggest Lateral-press P, When Cable Is Being Bent
The Single