This is the product title

Cross-linked PVC Sheathed XLPE Insulated High Voltage Power Cables 110 - 220KV - Product


Place of Origin : Beijing,China
Delivery Time : Negotiable

Product Description



Cross-linked PVC Sheathed XLPE Insulated High Voltage Power Cables 110 - 220KV



High-voltage 110~220KV XLPE Cable

Brief introduction of the 110~220KV XLPE high-voltage cable products:

1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable.

- - - -
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable for the places with a higher underground water level and t

Physical Specification

Other Specification :  Cross-linked PVC Sheathed XLPE Insulated High Voltage Power Cables 110 - 220KV High-voltage 110~220KV XLPE Cable Brief Introduction Of The 110~220KV XLPE High-voltage Cable Products: 1. The Cross-linkage PE Insulated And Wrinkled Aluminum Wrapper Waterproof PVC Sheathed Power Cable. - - - - Type | YJLW02, YJLLW02 | Specification | 240mm2~3000mm2 | Voltage | 110~220KV | Usage | Suitable For The Places With A Higher Underground Water Level And To Be Used Underground, In The Tunnels Or Pipes. Such Cables Bear A Bigger Pulling Force And Pressure. | - - - - 2.The Cross-linkage PE Insulated And Wrinkled Aluminum Wrapper Waterproof PE Sheathed Power Cable. - - - - Type | YJLW02, YJLLW02 | Specification | 240mm2~3000mm2 | Voltage | 110~220KV | Usage | Suitable For The Places With A Higher Underground Water Level And To Be Used Underground, In The Tunnels Or Pipes. Such Cables Bear A Bigger Pulling Force And Pressure. | - - - - Specific Property For Usage Of 110KV~220KV XLPE High-voltage Cable: 1. Cables Conductor Highest Working Temperature Is Allowed Up To 90, And Overload When Meet An Emergency Is 130 , When Short Circuit (in 5 Seconds) The Highest Temperature Is 250 2. When Installing Or Laying Cable, The Ambient Temperature Should Be Less Than -20, And Have To Give A Preheat To Cable. 3. The Minimum Bending Diameter: - - - - Cable Type Bending Diameter | Metal Sheathed | After Laying | 30D0 | During Laying | 40D0 | - - - - Note: In Form, D0 Is A Real Test Value To Cables Outer Diameter. 4. Allowed Biggest Axial Traction Force To Outer Diameter When Laying Cable (not Consider The Radial Lateral-pressure At Bent Set Ion) T=Kcore NO. Section (kg), In Formula, The Coefficient K Value Should Be: The Copper Core Get 7, The Aluminum Core Get 4. 5. Allowed Biggest Lateral-press P, When Cable Is Being Bent The Single Core Cabl

Company Inforamtion
Hebei New Baofeng Wire & Cable Co.,Ltd
[ Exporter - China ]
 : 6#,Taiping Street,Nanwei Road, Fuli Morgen Center E718, Xuanwu District Beijing
 : 86-10-59361676
 : highvolta@126.com
 : www.highvoltage-powercables.com

 : Yi Shen
 : 86-10-59361676
 : highvolta@126.com
View Profile



Top 3 in Electronics & Electrical



Top Products of Hebei New Baofeng Wire & Cable Co.,Ltd