This is the product title

multi-parameters patient monitor - Product


Place of Origin : Beijing,China
Payment Terms : T/T

Product Description

he parameters that the JB 9107 covers include: ECG, IBP(2 Channels),
NIBP, SPO2, Respiration, Pulse Rate, Temperature and
ETCO2. JB-9107 employs a 12” display to give detailed and clear
view to the caregiver. All the menus can be promptly accessed using
rotating knob, ensuring functions to be delivered decently during
operation. The built-in battery allows the monitor operated in patient
transfer and in case of an outage. Sophisticated networking design
gives the 9107 the abilit

Basic Information

Brand : JB

Physical Specification

Weight : 5kgs
Other Specification : Type :Portable Application :Adult, Pediatric And Neonatal Patients Classification :Types Of Protection: Class I Equipment Degree Of Protection: Type CF Defib-proof Safety: EN 60601-1 Display :Screen: 12.1” Full Color TFT Resolution: 800*600 Numerics: HR, ST Segment, PR, NIBP, (Systolic,Diastolic, MAP And PR), IBP1, IBP2, BR, EtCO2, Temp, %SpO2, Waveforms: Up To 6 Waveforms: ECG, IBP1,IBP2, Resp, CO2, SPO2 Sweep Speed: 12.5, 25, 50 Mm/sec (ECG, SpO2) 6.25 Mm/sec (Resp, CO2) Trend: Maximum 72 Hours Controls Function Keys: 6; Soft-moving Buttons Rotary Knob: Push And Rotate; 24 Steps/turn Alarm Audible : Volume Adjustable Visual: Figures Flashing Networking Ethernet LAN To 9100 Central Monitoring System Recorder Built-in, Thermal Array Width: Paper/Chart 50mm/48mm Paper Speed: 25mm/s ECG Five-lead And Twelve-lead Selectable: GND; Limb Leads I, II, III; Augmented Limb Leads AVL, AVR, AVF; Precordial Leads V1, V2, V3, V4, V5,V6 Displayed Waveforms: 2 Channels Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s Gain Selection: 6 Levels, Plus Auto HR Range Adult 20 € 300bpm Pediatric 20 € 350bpm Neonatal 20 € 350bpm Working Modes: Monitoring/Diagnostic/Surgery Test Signal: 1mV(displayed Via Touchkey) ST Detection: Yes Measuring Range: -2.0 ~2.0mv Alarm Preset: -2.0 ~ 2.0mv Overrun Alarm: Audible And Visual Alarm Will Function When A Preset Value Is Met. Electrosurgery Protection: Yes Defibrillator Protection: Yes CMRR: Monitoring Mode: >105dB Diagnostic Mode: >105dB Operating Mode: > 105dB Amplifier Bandwidth: 0.05 ~ 100Hz NIBP Technique: Oscillometric Measuring Parameters: Systolic, Diastolic, MAP, Pulse Rate. Operation Modes: Manual/Automatic/STAT Automatic Measurement Cycles: 1 ~ 90 Minutes; Factory Set: 5 Minutes Unit: MmHg/kPa Selectable Automatic Cuff Deflation: If Cuff Pres

Company Inforamtion
Jumbor Science & Technology Development Ltd.
[ Manufacturer - China ]
 : Suite 2903, Block B, Bldg 17(Riyue Tiandi) Zone 1, Fengchengyuan Fangzhuang, Fengtai Dist.
 : +86-10-58076638
 : vickyxu@jumbor.com.cn
 : www.jumbor.com.cn

 : VickyXu
 : +86-10-58076638
 : +86-15810805410~
 : vickyxu@jumbor.com.cn
View Profile



Top 3 in Health and Medical



Top Products of Jumbor Science & Technology Development Ltd.