(CE,FDA)Automatic Biochemistry Analyzer - Product
Place of Origin : Jinan,China
Delivery Terms : Sea/air
Delivery Time : Within 30days
Product Capacity : 685 Sets Per Month
Payment Terms : T/T.L/C
Product Description
Model: BIOBASE-CRYSTAL
Type: discrete, fully automatic
Throughput: 300T/H with single reagent
Analysis Method: end-point, fixed-time (two-point),kinetics,turbidimetry
Programming Items: programmable for any test items
Certification:CE,FDA,ISO9001,ISO14001,ISO13485
Working Temperature:15C~30C
Humidity: 35%~80%
Power Supply: AC220V+22V 50Hz+1Hz
Dimension:1020mm×830mm×1200mm (W*D*H)
Weight:130kg
Basic Information
Model : Crystal
Expiry/Validation Period : 1 Year
Physical Specification
Weight : 130kg
Other Specification : Model: BIOBASE-CRYSTAL
Type: Discrete, Fully Automatic
Throughput: 300T/H With Single Reagent
Analysis Method: End-point, Fixed-time (two-point),kinetics,turbidimetry
Programming Items: Programmable For Any Test Items
Certification:CE,FDA,ISO9001,ISO14001,ISO13485
Sample Unit:
Sample Settings:60 Sample Positions, Including Calibration, Quality Control And Emergency, Primary Tubes And Serum Is Available
Sample Volume: 2ul ~50ul (0.1ul Stepping)
Sample Probe: Having Liquid Level Induction Function, Ensuring The Accuracy Of Adding Sample
Probe Cleaning: Automatic Washing Both Interior And Exterior
Analysis Items: Analyzing Maximally 45 Items At The Same Time
Reagent Unit:
Reagent Position: 45 Low-temperature Refrigerated Reagent Position
Reagent Volume: R1:25~300ul, R2:10~150ul (1ul Stepping), Supporting Reagent From Different Countries
Temperature Control: Continuous 2C~8C Cooling Within 24 Hours
Reagent Probe: Having Liquid Level Induction Function, Ensuring The Accuracy Of Adding Reagent. Inventory Checking
Probe Cleaning: Automatic Washing Both Interior And Exterior
Reaction Unit:
Reaction Time: 10 Minutes
Cuvettes: 120 Independent Reaction Cuvettes (optical Path Length 6mm)
Stirrer:after Injecting Reagent And Sample, Blending Immediately
Cleaning: Automatic Water Cleaning And Drying System
Temperature Control: 37C±0.1C
System Adjustment: System Can Record The Blank Value And Get More Accurate Result By Deducting Blank Base Value Of Each Cuvette
Optical System:
Light Source: 12V/20W Halogen-tungsten Lamp, 2000 Hours
Receiver: 8 Imported Photo Receivers
Wavelength Range:340,405,450,510,546,578,630,700(three Of Them Can Be Defined By Users),adopting Reversed Optics
Testing Wavelength: Single And Double Wavelength Test
Calibration And QC:
Calibration: One-point, Multi-point
Linear Range: 0.000~2.500Abs