This is the product title

Rated Current 630 A 50 Hz 24kv VS1 Medium Voltage Circuit Breaker for 12kv Switchgear - [ Buy Service ]


Place of Origin : Ningbo,China
Post Date : 12-04-2012
Expiry Date : 12-05-2012


Trade Description

Rated Current 630 A 50 Hz 24kv VS1 Medium Voltage Circuit Breaker For 12kv Switchgear

5Main specifications and technical parameters(Refer to Tab 1)

Tab 1

- - - -
NO | Item | Unit | Technical Date |
1 | Rated voltage  | KV | 24 |
2 | Rated insulating level | Rated short time power  frequency withstand voltage(1min)           | 65 |
Rated lighting inpulse  withstand voltage (peak value)               | 125 |
3 | Rated Frequency | Hz | 50 |
4 | Rated current  | A | 630 |
5 | Rated short circuit breaking current         | KA | 20 |
6 | Rated short time withstand current            | 20 |
7 | Rated peak withstand current   | 50 |
8 | Rated short-circuit closing current (peak value) | 50 |
9 | 4S rated short-time withstand current  4s  | 20 |
10 | Rated Dynamic Current | 50 |
11 | Rated making surge current of capacitor bank | 12.5(The frequency  Is less than 1000Hz) |
12 | Rated breaking current of single/symmetrical capacitor bank  | A | 630/400                                |
13 | Duration of rated short-circuit current | S | 4 |
14 | Power frequency withstand voltage of secondary circuit | V | 2000 |
15 | Rated operationl voltage | Making coil | AC110/220   DC110/220 |
Breaking coil | AC110/220   DC110/220 |
Energy-storage motor  | AC110/220   DC110/220 |
16 | Making time  (under Rated voltage) | Ms | ≤60 |
17 | Breaking time(under Rated voltage) | ≤45 |
18 | Permitted abrasion thickness of moving and fixed contacts  | Mm | 3 |
19 | Energy storage times  | S | ≤15 |
20 | Contactor clearance | Mm | 13± 1 |
21 | Contacting travel  | 4±1  |
22 | Bounce time of Contactor during making  | Ms | ≤2 |
23 | Different time of breaking / making of 3 phases  | ≤2 |
24 | Average breaking speed  | 1.1-1.7 |
25 | Average making speed  | 0.6-1.1 |
26 | Rebound amplitude of contact breaking | Mm | ≤3 |
27 | Conductance circuit resistance  | µΩ | ≤45 (630A) |
28 | Rated operating sequence |   | O- θ -CO-180s-CO |
29 | Mechanical life | Times | 10000 |
- - - -

 

Outline Dimension Drawing

Dear friends,  please contact us for the outline dimension drawing,  we will give you quick reply.

Overview

VS1(ZN63A) series vacuum breaker is of indoor high voltage switchgear suitable for 24kV .

Three-phase power system with 50Hz frequency in order to protect and control electrical appliances,  

And especially suitable for frequent operation at rated current or incessant 

Open circuit due to unique advantages of vacuum circuit breaker.

Spring operating mechanism and breaker body parts adopt integration design.Thank for this design,  

Breaker not only can be a fixed installation unit ,  but also can be a withdraw-able unit with a specially pushing framework.

For meet the requirement of XGN2, GG1A cabinet ,  the fixed type breaker can be install additionally interlock.  

 

2Expression mode of product model

             V S 1 - 24 / □-□

 

         Rated short circuit breaking current kA

 

Rated current A

Rated voltage kV
3Product reference standard 
Shall be in accordance with standards in GB1984-89 Alternating Current High Voltage Breaker,  

JB3855-1996 3.6~40.5kV Indoor Alternating Current High Voltage Vacuum Breaker,  

And DL403-1999 Specification for Order of 10~35kV Indoor High Voltage Vacuum Breaker,  

And subject to relative requirements in IEC56 (87 publication).

 

 

 

 

 

 

 

 

 

 

 

 

 

4Operating environment condition

A) Normal operating environment condition

Highest temperature:                     +40ºC

Lowest temperature:                      -15ºC

B) Environment humidity

Daily average relative humidity:       ≤95%

Monthly average relative humidity:       ≤90%

Daily average saturated vapor pressure:  ≤2.2×10-3 MPa

Monthly average saturated vapor pressure:   ≤1.8×10-3 MPa

C) Altitude: below 1000m area;

D) Earthquake intensity: no more than 8 degree;

E) The product shall be away from weep,  fire and explosion,  

Chemical corrosion and strenuous vibration place.


Company Inforamtion
Ningbo Mingde Electrical Science&Technology Co.,Ltd
[ Exporter - China ]
 : 151Huapeng Road,Kandun Industrial Park,Cixi
 : 86-574-63287928
 : vacuumcircuit@126.com
 : www.vacuum-circuit-breakers.com

 : Alec Sunn
 : 86-574-63287928
 : 86-13625845635~
 : vacuumcircuit@126.com