JB3855 - 1996 VS1 Rated Short - Circuit Duration 4s Indoor 12kV Vacuum Circuit Breaker - [ Buy Service ]


Place of Origin : Ningbo,China
Post Date : 12-04-2012
Expiry Date : 12-05-2012


Trade Description

JB3855 - 1996 VS1 Rated Short - Circuit Duration 4s Indoor 12kV Vacuum Circuit Breaker

Main specifications and technical parameters(Refer to Tab 1)

Tab 1

- - - -
No | Item | Unit | Technical data |
1.  | Rated voltage | KV | 12 |
2.  | Rated short-time  Power frequency withstand voltage (1min) | 42 |
3.  | Rated lightning Impulse withstand voltage (peak value) | 75 |
4.  | Rated Frequency | Hz | 50 |
5.  | Rated current | A | 630 1250 | 630  1250 1600  2000 2500  3150 | 1250 1600 2000  2500  3150  4000* |
6.  | Rated short circuit breaking current | KA | 25 | 31.5 | 40 |
7.  | Rated short time withstand current | 25 | 31.5 | 40 |
8.  | Rated short-circuit duration | S | 4 |
9.  | Rated peak value withstand current | KA | 63 | 80 | 100 |
10.  | Rated short-circuit closing current (peak value) | 63 | 80 | 100 |
11.  | Secondary circuit power frequency Withstand voltage(1 min) | V | 2000 |
12.  | Rated single/ back-to-back capacitor bank Breaking current | A | 630/400 (40 kA for 800/400) |
13.  | Rated capacitor bank making rush Current | KA | 12.5(frequency  No more than 1000Hz) |
14.  | Opening time | Ms | 20~50 |
15.  | Closing time |   | 35~70 |
16.  | Mechanical life | Time | 10000   30000   60000 |
17.  | Breaking times at rated short-circuit current | Time | 50 (40 kA for 30) |
18.  | Permissible wear accumulated thickness Of moving and fixed contact | Mm | 3 |
19.  | Rated operating voltage of closing | V | AC 110/220   DC 110/220 |
20.  | Rated operating voltage of opening | AC 110/220   DC 110/220 |
21.  | Rated operating voltage of motor | AC 110/220   DC 110/220 |
22.  | Rated power of closing | W | 80  |
23.  | Stored energy time | S | ≤15 |
24.  | Contact clearance | Mm | 11±1 |
25.  | Super travel |   | 3.5±1 |
26.  | Contact closing bounce time | Ms | ≤2  |
27.  | Different duration of three-phase opening And closing |   | ≤2 |
28.  | Average opening speed(refers to the average speed  For first 6mm after opening of breaker contact) | M/s | 0.9~1.2 |
29.  | Average closing speed(refers to the average speed  for last  6mm before closing of breaker contact) |   | 0.5~0.8  |
30.  | Contact opening bounce amplitude value | Mm | ≤3 |
31.  | Conductance circuit resistance | µΩ | ≤50 (630A) ≤45 (1250A) ≤35(1600 ~ 2000A) ≤25(over  2500A) |
32.  | Contact closing contact pressure | N | 2400±200 ( 25 kA ) 3100±200 ( 31.5 kA ) 4250±250 ( 40 kA ) |
33.  | Rated operating order      |   | Opening -0.3S- closing/ Opening -180S-v |
- - - -

Outline Dimension Drawing

Dear friends,  pls contact us for the outline dimension drawing, We will give you quick reply.

Summary

VS1(ZN63A) series vacuum breaker is of indoor high voltage switchgear suitable for 12kV .

Three-phase power system with 50Hz frequency in order to protect and control electrical appliances, And especially suitable 

For frequent operation at rated current or incessant open circuit due to unique advantages of vacuum circuit breaker.

Spring operating mechanism and breaker body parts adopt integration design.Thank for this design,

 breaker not only can be a fixed installation unit ,  

But also can be a withdraw-able unit with a specially pushing framework.For meet the requirement of XGN2,

GG1A cabinet , The fixed type breaker can be install additionally interlock.  

 

2Expression mode of product model

                      V S 1 - 12 / □-□

         Rated short circuit breaking current kA

 

Rated current A

Rated voltage kV
3Product Reference Standard 
Shall be in accordance with standards in GB1984-89 Alternating Current High Voltage Breaker,  

JB3855-1996 3.6~40.5kV Indoor Alternating Current High Voltage Vacuum Breaker,  

And DL403-1999 Specification for Order of 10~35kV Indoor High Voltage Vacuum Breaker,  

And subject to relative requirements in IEC56 (87 publication).

 

4Operating environment condition

A) Normal operating environment condition

Highest temperature:                     +40ºC

Lowest temperature:                      -15ºC

B) Environment humidity

Daily average relative humidity:       ≤95%

Monthly average relative humidity:       ≤90%

Daily average saturated vapor pressure:  ≤2.2×10-3 MPa

Monthly average saturated vapor pressure:   ≤1.8×10-3 MPa

C) Altitude: below 1000m area;

D) Earthquake intensity: no more than 8 degree;

The product shall be away from weep,  fire and explosion,  chemical corrosion and strenuous vibration place.


Company Inforamtion
Ningbo Mingde Electrical Science&Technology Co.,Ltd
[ Exporter - China ]
 : 151Huapeng Road,Kandun Industrial Park,Cixi
 : 86-574-63287928
 : vacuumcircuit@126.com
 : www.vacuum-circuit-breakers.com

 : Alec Sunn
 : 86-574-63287928
 : 86-13625845635~
 : vacuumcircuit@126.com
View Profile


Top 3 Trades in Industrial Machinery & Services



Top Trade Leads of Ningbo Mingde Electrical Science&Technology Co.,Ltd