GB1984 Conductance Circuit Adopts Front and Rear Layout 12kv VMD2 Vacuum Circuit Breakers - [ Buy Service ]


Place of Origin : Ningbo,China
Post Date : 12-04-2012
Expiry Date : 12-05-2012


Trade Description

GB1984 Conductance Circuit Adopts Front And Rear Layout 12kv VMD2 Vacuum Circuit Breakers
Technical Parameters

- - - -
NO | Item | Unit | Technical Date |
1 | Rated voltage  | KV | 12 |
2 | Rated insulating level | Rated short time power  frequency withstand voltage(1min)           | 42 |
Raed lighting inpulse  Withstand voltage (peak value)               | 75 |
3 | Rated Frequency | Hz | 50 |
4 | Rated current  | A | 630 | 630 | 1250 | 1250 |
1250 | 1250 | 1600 | 1600 |
  |   | 2000 | 2000 |
2500 | 2500 |
3150 | 3150 |
4000 | 4000 |
5 | Rated short circuit breaking current         | KA | 20 | 25 | 31.5 | 40 |
6 | Rated short time withstand current            | 20 | 25 | 31.5 | 40 |
7 | Rated peak withstand current   | 50 | 63 | 80 | 100 |
8 | Rated short-circuit closing current (peak value) | 50 | 63 | 80 | 100 |
9 | 4S rated short-time withstand current  4s  | 20 | 25 | 31.5 | 40 |
10 | Rated shock steady current  | 50 | 63 | 80 | 100 |
11 | Rated making surge current of capacitor bank | 12.5(The frequency is less than 1000Hz) |
12 | Rated breaking current of single/symmetrical capacitor bank  | A | 630/400 (The value shoule be 800/400  While the current is 40kA)                                  |
13 | Duration of rated short-circuit current | S | 4 |
14 | Power frequency withstand voltage of secondary circuit | V | 2000 |
15 | Rated operationl voltage | Making coil | AC110/220   DC110/220 |
Breaking coil | AC110/220   DC110/220 |
Energy-storage motor  | AC110/220   DC110/220 |
16 | Making time  (under Rated voltage) | Ms | 35-70 |
17 | Brealing time(under Rated voltage) | 20-45 |
18 | Permitted abrasion thickness of moving and fixed contacts  | Mm | 3 |
19 | Energy storage times  | S | ≤15 |
20 | Contactor space | Mm | 9± 1 |
21 | Contacting travel  | 3---4 |
22 | Bounce time of Contactor during making  | Ms | ≤2 |
23 | Different time of breaking / making of 3 phases  | ≤2 |
24 | Average breaking speed  | 0.9-1.3 |
25 | Average making speed  | 0.4-0.8 |
26 | Rebound amplitude of contact breaking | Mm | ≤3 |
27 | Conductance circuit resistance  | µΩ | ≤50 (630A) |
≤45(1250A) |
≤35(1600A-2000A) |
≤25(More than 2500A)  |
28 | The contacting pressure of of contactor during making | N | 2000±200(20kA) |
2400±200(35kA) |
3100±200(31.5kA) |
4750±250(40kA) |
29 | Rated operating sequence |   | O- θ -CO-180s-CO |
The average breaking speed is that of contactor’s first 6mm .  The average making speed refers to the average speed of total Contactor space . When the rated short circuit breaking current is less than 40kA,  θ is equal to 0.3S.  When the short circuit breaking current is more than or equal to  40kA,  θ is equal to 180S |
- - - -

Summary

The VMD2 series indoor circuit-breaker is our independent developed new generation 12 kv vacuuum circuit breaker. 

Its main characters as follows: the conductance circuit is installed in an three-phase insulating sleeve ,

 its mechanism and conductance circuit adopts front and rear layout. 

And the mechanism is our deveoped new design,  with simple construction,

 reliable operation, And rich manufacturing experiences of million sets ,  

Used  and learned by many high-end vacuum circuit breaker manufacturers.

 

Technical standard

All the technical parameters of breaker completely satisfy the Standards Of GB1984 AC Highvoltage Breaker,  

GB/T 11022 -1999 Common Specifications For High-Voltage Switchgear And Controlgear Standards,  

China Power Sector Standards DL403.

Also meet the requirements of IEC62271-100,  IEC56 and other main industrialized country’s similar standards

 

Testing

VMD2 series circuit breaker have passed has passed following 

Test ,  to ensure the product’s safe Operation.

 

Type tests : power-frequency withstand voltage tests ,  lighting impact withstand voltage tests,  ,  

Temperature rising tests,  short-time withstand current tests ,  

Peak withstand current tests , Short circuit breaking ability tests ,  mechanical lift tests, Ect

 

Routine test before out of factory: mechanical performance test  ,  power-frequency withstand voltage tests of the main circuit ,  

Insulating property  tests on control and auxiliary circuits , Measurement of ther resistance of the main circuit ,

 interlock operating tests ,  mechanical operating tests,  Electrical Equipment operating tests.

 

Scope of application

 

 

It is universally used in power plant ,  electric network ,  

Metallurgy industry petrochemical industry and infrastructures, Such as airport ,  subway,  building.

VMD2 circuit breaker can be applied to control and protect cable ,

 trolly wire , Transformer,  generator and capacitor bank in distribution system

 

Safety

VMD2  circuit breaker possesses  perfect mechanical and electric interlock equipment ,  meanwhile ,

Its high reliable operating performance and mechanical life ,  

Coodinated with matched switchgear cabinet , To ensure normal power distribution ,  operator and equipment’s safety.

Outline Dimension Drawing

Dear friends,  pls contact us for the outline dimension drawing, We will give you quick reply.


Company Inforamtion
Ningbo Mingde Electrical Science&Technology Co.,Ltd
[ Exporter - China ]
 : 151Huapeng Road,Kandun Industrial Park,Cixi
 : 86-574-63287928
 : vacuumcircuit@126.com
 : www.vacuum-circuit-breakers.com

 : Alec Sunn
 : 86-574-63287928
 : 86-13625845635~
 : vacuumcircuit@126.com
View Profile


Top 3 Trades in Industrial Machinery & Services



Top Trade Leads of Ningbo Mingde Electrical Science&Technology Co.,Ltd