AC110 / 220, DC110 / 220 Energy Storage Times ≤ 15S 12kv VMD2 Vacuum Circuit Breaker
Technical Parameters
- - - -
NO | Item | Unit | Technical Date |
1 | Rated voltage | KV | 12 |
2 | Rated insulating level | Rated short time power frequency Withstand voltage(1min)          | 42 |
Raed lighting inpulse withstand  voltage (peak value)              | 75 |
3 | Rated Frequency | Hz | 50 |
4 | Rated current | A | 630 | 630 | 1250 | 1250 |
1250 | 1250 | 1600 | 1600 |
  |   | 2000 | 2000 |
2500 | 2500 |
3150 | 3150 |
4000 | 4000 |
5 | Rated short circuit breaking current        | KA | 20 | 25 | 31.5 | 40 |
6 | Rated short time withstand current           | 20 | 25 | 31.5 | 40 |
7 | Rated peak withstand current  | 50 | 63 | 80 | 100 |
8 | Rated short-circuit closing current (peak value) | 50 | 63 | 80 | 100 |
9 | 4S rated short-time withstand current  4s | 20 | 25 | 31.5 | 40 |
10 | Rated shock steady current | 50 | 63 | 80 | 100 |
11 | Rated making surge current of capacitor bank | 12.5(The frequency Is less than 1000Hz) |
12 | Rated breaking current of single/symmetrical capacitor bank | A | 630/400 (The value Shoule be 800/400 While the current is 40kA)                                 |
13 | Duration of rated short-circuit current | S | 4 |
14 | Power frequency withstand voltage of secondary circuit | V | 2000 |
15 | Rated operationl voltage | Making coil | AC110/220   DC110/220 |
Breaking coil | AC110/220   DC110/220 |
Energy-storage motor | AC110/220   DC110/220 |
16 | Making time  (under Rated voltage) | Ms | 35-70 |
17 | Brealing time(under Rated voltage) | 20-45 |
18 | Permitted abrasion thickness of moving and fixed contacts | Mm | 3 |
19 | Energy storage times | S | ≤15 |
20 | Contactor space | Mm | 9± 1 |
21 | Contacting travel | 3---4 |
22 | Bounce time of Contactor during making | Ms | ≤2 |
23 | Different time of breaking / making of 3 phases | ≤2 |
24 | Average breaking speed | 0.9-1.3 |
25 | Average making speed | 0.4-0.8 |
26 | Rebound amplitude of contact breaking | Mm | ≤3 |
27 | Conductance circuit resistance | µΩ | ≤50 (630A) |
≤45(1250A) |
≤35(1600A-2000A) |
≤25(More than 2500A) |
28 | The contacting pressure of of contactor during making | N | 2000±200(20kA) |
2400±200(35kA) |
3100±200(31.5kA) |
4750±250(40kA) |
29 | Rated operating sequence |   | O- θ -CO-180s-CO |
The average breaking speed is that of contactor’s first 6mm . The average making speed refers to the average speed of total Contactor space . When the rated short circuit breaking current is less than 40kA,  θ is equal to 0.3S. When the short circuit breaking current is more than or equal to  40kA,  θ is equal to 180S |
- - - -
Outline Dimension Drawing
Dear friends,  pls contact us for the outline dimension drawing, We will give you quick reply.
Summary
The VMD2 series indoor circuit-breaker is our independent developed new generation 12 kv vacuuum circuit breaker. Its main characters as follows:ÂÂ
The conductance circuit is installed in an three-phase insulating sleeve ,
 its mechanism and conductance circuit adopts front and rear layout.ÂÂ
And the mechanism is our deveoped new design,  with simple construction, ÂÂ
Reliable operation, And rich manufacturing experiences of million sets , ÂÂ
Used  and learned by many high-end vacuum circuit breaker manufacturers.
ÂÂ
Technical standard
All the technical parameters of breaker completely satisfy the Standards Of GB1984 AC Highvoltage Breaker, ÂÂ
GB/T 11022 -1999 Common Specifications For High-Voltage Switchgear And Controlgear Standards, ÂÂ
China Power Sector Standards DL403.
Also meet the requirements of IEC62271-100,  IEC56 and other main industrialized country’s similar standards
ÂÂ
Testing
VMD2 series circuit breaker have passed has passed followingÂÂ
Test ,  to ensure the product’s safe Operation.
ÂÂ
Type tests : power-frequency withstand voltage tests ,  lighting impact withstand voltage tests,  ,
 temperature rising tests,  short-time withstand current tests ,  peak withstand current tests ,
Short circuit breaking ability tests ,  mechanical lift tests, Ect
ÂÂ
Routine test before out of factory: mechanical performance test  ,  power-frequency withstand voltage tests of the main circuit ,  insulating property  tests on control and auxiliary circuits ,
Measurement of ther resistance of the main circuit ,  interlock operating tests ,  mechanical operating tests, ÂÂ
Electrical Equipment operating tests.
ÂÂ
Scope of application
ÂÂ
ÂÂ
It is universally used in power plant ,  electric network ,  metallurgy industry petrochemical industry and infrastructures,
Such as airport ,  subway,  building.
VMD2 circuit breaker can be applied to control and protect cable ,  trolly wire , Transformer, ÂÂ
Generator and capacitor bank in distribution system
ÂÂ
Safety
VMD2  circuit breaker possesses  perfect mechanical and electric interlock equipment ,  meanwhile ,
Its high reliable operating performance and mechanical life ,  coodinated with matched switchgear cabinet ,
To ensure normal power distribution ,  operator and equipment’s safety.