This is the product title

Power factor correction---TSC/TSF - Product


MINIMUM QUANTITY

1SET

Place of Origin : Zhuhai,China
Delivery Terms : 30days
Product Capacity : 500 Sets / Year
Payment Terms : TT, L/C

Product Description

Stabilize busbar voltage
Improve power factor
Eliminate harmonic current
Decrease grid loss
Suppress harmonic resonance


Rated voltage AC220V~1140V
Operation voltage 0.8~1.1Un
Rated frequency 50Hz/60Hz (Option)
Capacitor wiring mode Delta/Star(Option)
Switching mode Cycle/sequence/coded combination (Option)
Response time <20ms
Allowable maximum over current 1.3 times of rated current
Control steps 1~12/1~16 (Option)
Switching characteristic Current zero-crossing switching

Basic Information

Brand : Wanlida
Model : WLD-TSC

Physical Specification

Size or Volume : Depending On Specification
Weight : Depending On Specification
Other Specification : Wanlida Power Factor Correction Device Introduction: Based On DSP Control Technology And Instantaneous Power Control Theory, Wanlida Power Factor Correction Device (TSC/TSF) With High-speed Switching Capability Are Designed To Support The Supply Voltage Of Distribution Systems And To Correct The Power Factor And Eliminate The Harmonic Current Of Connected Loads. Thyristor Zero-crossing Switching Switches Are Resistant To Mechanical Wear, Operate Without Noise, And Are Capable Of Practically Transient-free Switching, So It Is More Safety Than Contactor Switched Capacitor Banks. Functions: Improve Power Factor Stabilize Busbar Voltage And Suppress Subsynchronous Resonance Eliminate Harmonic Current Decrease Grid Loss Optimize Reactive Power Increase Transformer Loading Capacity Principles: Power Factor Correction Device Is The Compensating Device Based On Switching Operation Of Capacitor Banks By Thyristor. It Mainly Consists Of Control System, Thyristor, Capacitors And Reactors. Capacitor Banks Are Divided Into Multiple Units To Realize Step Control. Power Factor Correction Is Able To Implement Step Regulating In Reactive Power, Accuracy Of Regulating Depends On Numbers Of Multiple Unit. Power Factor Correction (TSC/TSF) Apply Delta Wiring. To Optimize Effect Of Reactive Power Compensating And Harmonic Filtering, TSC Capacity And Branch Configuration Must Be Designed According To Reactive Power Variation And Harmonic Components From Nonlinear Load.

Company Inforamtion
Zhuhai Wanlida Electric Co.,Ltd
[ Manufacturer - China ]
 : Relay Protection Industrial Park, No.1 Technology Road, Science and Technology Innovation Coast, High-tech Zone
 : 86-756-3395623
 : wanlidasales@hotmail.com
 : www.elecequipment.com

 : Ashley Lin
 : 86-756-3395623
 : 86-15989754164~
 : wanlidasales@hotmail.com
View Profile



Top 3 in Power & Generators