This is the product title

Adjustable Bimetallic Steam Trap Automatic For Radiator , Jacketed Kettle - Product


Place of Origin : Beijing,China

Product Description

Adjustable Bimetallic Steam Trap Automatic For Radiator , Jacketed Kettle



Quick Details:
Temperature: 425 Working Media: Steam, Condensate Water End Connection: Flange, Screw & Socket Welded Adjustable Discharging Temp

Specifications:
Thermostatic Steam Traps
Tight Shut-off With SCCV System
Adjustable Discharging Temp
Water Seal No Steam Loss
Installed In Any Direction

Design Pressure: PN25
Preesure: 0.01 - 1.6 Mpa Material: WCB & A105 Temperature: 425 Working

Physical Specification

Other Specification : Adjustable Bimetallic Steam Trap Automatic For Radiator , Jacketed Kettle Quick Details: Temperature: 425 Working Media: Steam, Condensate Water End Connection: Flange, Screw & Socket Welded Adjustable Discharging Temp Specifications: Thermostatic Steam Traps Tight Shut-off With SCCV System Adjustable Discharging Temp Water Seal No Steam Loss Installed In Any Direction Design Pressure: PN25 Preesure: 0.01 - 1.6 Mpa Material: WCB & A105 Temperature: 425 Working Media: Steam, Condensate Water End Connection: Flange, Screw & Socket Welded Bimetallic Steam Trap / Thermostatic Steam Trap TB11: # 1. Tight Shut-off And Long Service Life By Using SCCV System. # 2. Efficient In Energy Saving---adjustable Discharging Temperature And Effectively Using The Sensible Heat Of Hot Condensate. # 3. Discharging Temperature Can Be Adjusted When The Pipe Net Is In Operation. Can Be Installed In Any Direction. # 4. Hot Condensate Exists Just Before The Trap, Forming A Tight Water Seal, Which Ensures No Steam Loss. # 5. Withstands Water Hammer With Outstanding Performance Of Air Venting. # 6. Operating Without Noise, Benefiting For Environmental Protection. # 7. Full Open At The Beginning Of Steam Supplying, Discharging Cold Condensate And Air Rapidly, Which Ensures Quick Start-up. # 8. Stainless Steel Internals Are Resistant To Corrosion And Cavitation. Small In Size And Light In Weight, Easy Maintenance. Application: This Steam Trap Is Suitable For Steam Main Pipe, Steam Tracer, Radiator, Low Temperature Heating Trough, Jacketed Kettle And Heating System Etc... Note: This Steam Trap's Insulation Is Not Recommended For Pipe Section 1 Meter Before The Trap And The Trap Itself.

Company Inforamtion
Beijing 920 Technology Co., Ltd.
[ Indenter - China ]
 : Room2501, Building #2, Soubao Business Center, Fengtai District, Beijing, China
 : 86-10-63326243
 : hongfengco@126.com
 : www.hongfeng920.com/

 : Beijing 920 Technology Co., Ltd.
 : 86-10-63326243
 : hongfengco@126.com
View Profile