This is the product title

CE Approved Dental X-ray Tube for Replacement TOSHIBA X ray film machine tubes 70kV , O.4 Focal Spot - Product


Place of Origin : Hangzhou,China
Delivery Time : 30DAYS

Product Description





CE Approved High Frequency Dental X-ray Tube for Replacement TOSHIBA X ray film machine tubes 70kV O.4 Focal Spot



Quick Detail:



Type:Station anode x-ray tube

Application: For dental radiography unit

Model: KL11-0.4-70

Equivalent to TOSHIBA D-0411

Integrated high quality glass tube



Description:



KL11-0.4-70 Stationary anode X-Ray Tube is especially designed for high frequency intra-oral dental x-ray unit and available for a nominal tube voltage with

Physical Specification

Other Specification :  CE Approved High Frequency Dental X-ray Tube For Replacement TOSHIBA X Ray Film Machine Tubes 70kV O.4 Focal Spot Quick Detail: Type:Station Anode X-ray Tube Application: For Dental Radiography Unit Model: KL11-0.4-70 Equivalent To TOSHIBA D-0411 Integrated High Quality Glass Tube Description: KL11-0.4-70 Stationary Anode X-Ray Tube Is Especially Designed For High Frequency Intra-oral Dental X-ray Unit And Available For A Nominal Tube Voltage With DC. KL11-0.4-70 Tube Has One Focus. The Integrated High Quality Tube With Glass Design Has One Super Imposed Focal Spot And A Reinforced Anode. The High Anode Heat Storage Capacity Ensures A Wide Range Of Applications For Intra-oral Dental Application. A Special Designed Anode Enables An Elevated Heat Dissipation Rate Which Leads To A Higher Patient Throughput And A Longer Product Life. A Constant High Dose Yield During The Entire Tube Life Is Ensured By The High Density Tungsten Target. Ease Of Integration Into System Products Is Facilitated By Extensive Technical Support. Applications: KL11-0.4-70 Stationary Anode X-Ray Tube Is Especially Designed For High Frequency Intra-oral Dental X-ray Unit And Available For A Nominal Tube Voltage With DC. Specifications: Maximum Tube Voltage......70kV MaximumTube Current.......9mA Maximum Power (at 1.0s)................430 W Maximum Anode Cooling Rate110W Max.Anode Heat Content..........4.3kJ Filament Characteristics...Ifmax=3.0A,Uf=3.20.5V Focal Spot .....0.4(IEC 60336 2005) Target Angle...12 Target Material...Tungsten Cathode Type...W Filament Permanent Filtration.......Min. 0.5mmAl/50 KV(IEC60522/1999) Dimensions...67mm Length By 30mm Diameter Weight..100 Grams Competitive Advantage: Available For The DC Generator Constant High

Company Inforamtion
Hangzhou Dongzi Import & Export Co., Ltd
[ Exporter - China ]
 : No.30, Nongjudian, Liuxia Zhen, West Lake District
 : 86-571-85229706
 : dentalxraytube@126.com
 : www.dentalx-raytube.com/

 : Miss. Lily
 : 8657185229706
 : dentalxraytube@126.com
View Profile



Top 3 in Electronics & Electrical



Top Products of Hangzhou Dongzi Import & Export Co., Ltd