This is the product title

Solar Charge Controller for SHS (CMP45-30A, 12/24V Auto, 48V)Auto) - Product


UNIT PRICE

54.00
MINIMUM QUANTITY

1PC
WARRANTY

1YEAR

Place of Origin : Shenzhen,China
Delivery Terms : FOB
Delivery Time : 7days
Payment Terms : T/T

Product Description

Technical Specification:
Mode: CMP45-30A, 45A
Voltage(DC): 12V/24V Automatically distinguish /48V
Max Load Current: ≤ 30A, ≤ 45A
Full Charge Cut: 13.7V/12V; × 2/24V; × 4/48V
Resume Voltage: 12.6V/12V; × 2/24V; × 4/48V
Low Voltage Cut: 10.5V/12V; × 2/24V; × 4/48V
Temp Compensation: -3mv/cell, Default, or user set
Zero Load Loses: ≤ 45mA
Min Wire Size: 6 mm2
Voltage Drop: <520mv; <600mv

Basic Information

Brand : Golandcentury
Model : CMP45-30A, 45A
Material : Solar
Color : Black
Expiry/Validation Period : One Month

Physical Specification

Other Specification : Feature: CPU Controlled CMP45 (30A, 45A) Solar Charge Controller Is Able To Adjust The Charge Current And Decide If To Supply The Loads Electricity According To The Voltage Of Battery. The Product Also Has Following Features: 1. Generally Keep The Battery On Full Voltage Condition. 2. Prevent The Battery From Over-charging. 3. Prevent The Battery From Over-discharging. 4. Prevent Supplying Electricity From The Battery To Solar Panels During Nights. 5. Reverse Polarity Protection For Battery 6. Reverse Polarity Protection For Solar Panels 7. When The Current Of Load Exceeds The Rated One Of Controller, The Controller Will Activate The Protection Mode And Lock Up, The Screen Shows "Overload". 8. When Short Circuit Happens, The Controller Will Activate The Protection Mode And Lock Up, The Screen Show "Short Circuit". 9. When The Battery's Voltage Is Low, The Controller Will Automatically Cut Off Loads From System And Resume Its Working Once The Voltage Of Battery Is Back To Normal. 10. Protection From The Lightning Strike 11. When Controller Is Normally Working, The LCD Screen Will Show The Voltage Of Battery, Charging Current And Current Of Loads In Turn In Every 5 Seconds. 12. Controller Is Always Counting And Saving The Charging Current Hours And Discharging Current Hours Of The Battery. 13. When Controller Starts Up, Controllers Will Self-setup The Charging-off Voltage, The Load-off Voltage And The Load-on Voltage According To The Voltage Of Battery. These Default Parameters Are Setup As The Standard Environment Temperature Is 25 Degrees Celsius. 14. According To Vary System Temperature; The Controller Will Automatically Compensate The Temperature Of The Charging Voltage. 15. Users Could Setup The Charge-on Or Off Voltage, The Load-off Voltage, The Load-on Voltage, Etc, According To Their Requirements. 16. To Prevent Battery From Ove

Company Inforamtion
Goland Century Co.,Ltd
[ Manufacturer - China ]
 : Room 220, Material building, Houhai street, Nanshan district,Shenzhen China.
 : +86-755-26827242
 : terry@golandcentury.com
 : www.golandcentury.com

 : Terry Quan
 : +86-755-26827242
 : terry@golandcentury.com
View Profile



Top 3 in Electronics & Electrical



Top Products of Goland Century Co.,Ltd