1. Performance
This product adopted PIC technology to control the pure sine wave output, stable output voltage, accurate output frequency, super discharge waveform, THD (Total Harmonic Distortion) ≤ 3%, including Auto hibernation function which could decrease the own-consumption. At the same time this inverter also has over-discharging protection, overload protection, short circuit protection and so on.
Basic Information
Brand : Goland Century
Physical Specification
Other Specification : (1) Auto Hibernate Function:
When There Is No AC Output Or The Load Power Less Than 15watt, The Inverter Will Be Auto Hibernated In Order To Decrease Own Consumption. The Inverter Will Restart Each 10 Second During Hibernation, And Automatically Check The AC Load. If There Is No AC Load, The Inverter Will Default Hibernation Again. If There Is AC Output, The Inverter Will Be Back Power Supply State.
(2) Low Battery Shut Down Protection:
When The Utility Power Is Not Available, Continuous Use Inverter To Offer Power For Your Electric Appliance Could Cause The Voltage Of The Battery Get Down Serious, It Will Be Enormously Affect The Lifetime Of The Battery. This Inverter Could Start To Protect Function When The Voltage Of The Battery Gets Down The Settled Point. (Refer Item 6) Protected The Battery From Over Discharge Damage.
(3) Soft-start System Protection:
High Startup Currents From Large Inductive Loads Could Shut Down The Inverter, It Will Affect The Lifetime Of The Inverter. We Suggest You Use Our Soft Start Function: The Inverter Stay In Close Condition, Connect The Load To The Inverter, And Open The Power Switch Of The Large Loads Firstly, Then Start The Inverter To Offer Power For Your Loads. At The Beginning The Output Voltage Of The Inverter Is Very Small, There Is Not Large Surge Current Affect The Inverter, After Period Of Time The Output Voltage Will Reach To Rated Output Voltage.
(4) Output Overload Protection:
This Inverter Have Rated Power. (Refer Item6) If The Power Of The Load More Than Rated Power Of The Inverter, The Inverter Will Start Overloading Protection And Alarm. (Refer Item4) Please Turn Off Some Electric Appliances In Order To Decrease The Load At This Time. Then The Inverter Will Recover Normal Working. If The Inverter Continues Overload Working, It Will Shut Down With A Small Delay In Order To Avoid Damaging The Produc