This is the product title

Testing Ionized Water Testing Equipments 3 * 1.5V With Screwdriver - Product


Place of Origin : Guangzhou,China
Delivery Time : Within 7 Working Days

Product Description



Testing Ionized Water Ttesting Equipments 3 * 1.5V With Screwdriver





Specifications

Water pH meter for testing ionized water

- - - -
Digital pH meter: pH adjustable. |
Range:0.0-14.0 PH |
Resolution:0.1 PH |
Accuracy: 0.1 PH(at 20C/ F) |
Typical EMC DEV: 0.2 PH |
Batteries: 3*1.5V ( AG-13 Button Battery) |
Life: approx*700 hours of use |
Environment: 0C-50C (32F-122F) |
Relative Humidity: less than 95% |
Dimensions: 150mm*29mm*20

Physical Specification

Other Specification :  Testing Ionized Water Ttesting Equipments 3 * 1.5V With Screwdriver Specifications Water PH Meter For Testing Ionized Water - - - - Digital PH Meter: PH Adjustable. | Range:0.0-14.0 PH | Resolution:0.1 PH | Accuracy: 0.1 PH(at 20C/ F) | Typical EMC DEV: 0.2 PH | Batteries: 3*1.5V ( AG-13 Button Battery) | Life: Approx*700 Hours Of Use | Environment: 0C-50C (32F-122F) | Relative Humidity: Less Than 95% | Dimensions: 150mm*29mm*20mm | Weight: 55g | Trimming: By Potentiometer | Certificate: CE And ROHS | - - - - Operation Remove The Protective Cap First Rinse The Electrode With Distilled Water, And Suck It With Filter-paper. Turn On PH By ON-OFF Switch Located On The Top Of Battery Case Immerse The PH Meter Electrode In The Solution To Be Tested. Stir Gently And Wait For The Reading To Stabilize. After Use, Switch Off PH, Use The Distilled Water Clean The Electrode And Replace The Protective Cap. PH Calibration 1. Immerse The Electrode In PH 6.86(under The Temperature Of 25C) Standard Buffer Solution Of Phosphate, And Gently Shake The Electrode. 2. Regulate The Trimmer With A Screwdriver Until The Buffer Solution Value Corresponding To The Measurement Temperature Is Obtained. 3. Immerse The Electrode In PH4.01 Or PH9.18 The Standard Buffer Solution Of Borax. 4. After About One Minute, Until The Buffer Solution Value Corresponding To The Measurement Temperature Is Obtained. Important: The Instruments PH Range Must Be Re-calibrated Whenever. The Electrode Has Been Used(laid) For Long Time From The Last Calibration. The Electrode Has Been Used In Particularly Taxing Conditions. The Utmost Accuracy Is Required. Battery Install If The Display Of Meter Fades To Replace All The Batteries. Pull Out The Battery Case And Replace The Batteries. Pay Atten

Company Inforamtion
EHM Group Ltd
[ Exporter - China ]
 : No.2981 Ke JI Yuan, Nanshan District, Shenzhen, GuangDong, China.
 : 86-0755-25812866
 : productkeycodes@126.com
 : www.product-key-codes.com/

 : Ms. VICKY
 : 86075525812866
 : productkeycodes@126.com
View Profile



Top 3 in Electronics & Electrical



Top Products of EHM Group Ltd