This is the product title

AA500F Atomic Absorption Spectrophotometer Flame AA System 0.1 0.2 0.4 1.0 2.0nm - Product


Place of Origin : Beijing,China
Delivery Time : Contact For Confirmation

Product Description

Flame AA System AA500F 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer




The flame atomizer offers three flame options: Air/Acetylene is the standard configuration with the N2O/acetylene and Air/LPG as options.



Air/Acetylene
The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration
The high sensitivity (Cu 2ppm>0.280Abs) is due to the efficiency of the fixed position glass nebulizer fitted as standard. An acid resistant replacement is availa

Physical Specification

Other Specification : Flame AA System AA500F 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer The Flame Atomizer Offers Three Flame Options: Air/Acetylene Is The Standard Configuration With The N2O/acetylene And Air/LPG As Options. Air/Acetylene The Air/Acetylene Flame Uses A 100mm Single Slot Burner For The Standard Configuration The High Sensitivity (Cu 2ppm>0.280Abs) Is Due To The Efficiency Of The Fixed Position Glass Nebulizer Fitted As Standard. An Acid Resistant Replacement Is Available As An Option. The Flame Can Be Easily Set From Blue Lean Flame Through Stoichiometric To Fuel Rich By Means Of Computer Control N2O/Acetylene The N2O/Acetylene Flame Uses A 50mm Single Slot Burner And Is Available As An Optional Extra. This Flame Configuration Is Used To Measure Elements Less Prone To Ionization Such As Aluminum, Tin, Titanium, Calcium, Vanadium And Molybdenum. Switching From Air/Acetylene To N2O/Acetylene To Flame Off Is Fully Controlled By The AAWin Pro Software Air/Propane (LPG) This Flame Uses A 3 Slot Burner And With The Low Pressure Requirement It Is Also Much Safer To Operate Due To The Low Temperature Of The Flame It Is Ideal For Analyzing Alkali Metals Such As Potassium, Sodium And Lithium, Especially When Used In The Emission Mode. Some Remote Areas Of The World Have Difficulty Obtaining Acetylene Gas Of A High Enough Purity To Operate The Flame Correctly. LPG Can Give A Real Alternative And Offer Comparable Results For Most Elements Throughout The Wavelength Range. Safety Features Pressure Monitoring For All Gases Burner Identification Flame Sensor Drain Trap Level Sensor Gas Leak Detector Over Pressure In Premix Safety Cut Off Switch Applications: Agricultural Clinical Environmental Food Metal Mining Geological Pertrochemical Pharmaceutical Specifications: - - - - SpectrometerSystem

Company Inforamtion
Beijing Purkinje General Instrument Co., Ltd.
[ Exporter - China ]
 : China Office: No.3 Pingsan Road, Pinggu District
 : 86-010-69910653
 : labdevice@126.com
 : www.lab-device.com/

 : Miss. April Cao
 : 8601069910653
 : labdevice@126.com
View Profile



Top 3 in Advertising



Top Products of Beijing Purkinje General Instrument Co., Ltd.